@@ -35,6 +35,7 @@ namespace CapMachine.Wpf.Services
public AlarmService AlarmService { get; }
public ConfigService ConfigService { get; }
public CanDriveService CanDriveService { get; }
public CanFdDriveService CanFdDriveService { get; }
public LinDriveService LinDriveService { get; }
public SysRunService SysRunService { get; }
@@ -118,7 +119,7 @@ namespace CapMachine.Wpf.Services
/// </summary>
/// <param name="eventAggregator"></param>
public MachineRtDataService(IEventAggregator eventAggregator, AlarmService alarmService, ConfigService configService,
CanDriveService canDriveService, LinDriveService linDriveService, SysRunService sysRunService)//, AlarmService alarmService
CanDriveService canDriveService, CanFdDriveService canFdDriveService, LinDriveService linDriveService, SysRunService sysRunService)//, AlarmService alarmService
{
//ConcurrentDictionary<DateTime, RecordInfo> keyValuePairs = new ConcurrentDictionary<DateTime, RecordInfo>();
@@ -136,6 +137,7 @@ namespace CapMachine.Wpf.Services
AlarmService = alarmService;
ConfigService = configService;
CanDriveService = canDriveService;
CanFdDriveService = canFdDriveService;
LinDriveService = linDriveService;
SysRunService = sysRunService;
@@ -1193,6 +1195,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)CanDriveService.GetDbcSpeedValueBySpeedName("通讯Cmp转速"));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)CanFdDriveService.GetDbcSpeedValueBySpeedName("通讯Cmp转速"));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)LinDriveService.GetLdfSpeedValueBySpeedName("通讯Cmp转速"));
@@ -1212,6 +1219,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp母线电压") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp母线电压") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp母线电压") * itemTag.Value.Precision));
@@ -1230,6 +1242,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp母线电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp母线电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp母线电流") * itemTag.Value.Precision));
@@ -1248,6 +1265,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp相电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp相电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp相电流") * itemTag.Value.Precision));
@@ -1266,6 +1288,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp功率") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp功率") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp功率") * itemTag.Value.Precision));
@@ -1284,6 +1311,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp芯片温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp芯片温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp芯片温度") * itemTag.Value.Precision));
@@ -1302,6 +1334,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯Cmp逆变器温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯Cmp逆变器温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯Cmp逆变器温度") * itemTag.Value.Precision));
@@ -1320,6 +1357,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC入水温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC入水温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC入水温度") * itemTag.Value.Precision));
@@ -1338,6 +1380,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC出水温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC出水温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC出水温度") * itemTag.Value.Precision));
@@ -1356,6 +1403,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC峰值电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC峰值电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC峰值电流") * itemTag.Value.Precision));
@@ -1374,6 +1426,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC母线电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC母线电流") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC母线电流") * itemTag.Value.Precision));
@@ -1392,6 +1449,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC膜温") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC膜温") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC膜温") * itemTag.Value.Precision));
@@ -1410,6 +1472,11 @@ namespace CapMachine.Wpf.Services
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanDriveService.GetDbcValueByName("通讯PTC模块温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(CanFdDriveService.GetDbcValueByName("通讯PTC模块温度") * itemTag.Value.Precision));
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//通信转速 Dbc中间配置名称的转速数据读取出来 给PLC
SiemensDrive.Write(itemTag.Value.PVAddress, (short)(LinDriveService.GetLdfValueByName("通讯PTC模块温度") * itemTag.Value.Precision));
@@ -1444,6 +1511,15 @@ namespace CapMachine.Wpf.Services
itemTag.Value.EngPvValue = CanDriveService.GetDbcValueByName(itemTag.Value.NameNoUnit);
}
break;
case CanLinEnum.CANFD:
//CAN数据读取 //回读CAN通信的数据到集合中
//CAN组合并且在循环接收数据中时才读取数据
if (itemTag.Value.Group == "CANLIN")
{
//回读CAN通信的DBC集合数据到集合中
itemTag.Value.EngPvValue = CanFdDriveService.GetDbcValueByName(itemTag.Value.NameNoUnit);
}
break;
case CanLinEnum.Lin:
//LIN数据读取 //回读LIN通信的数据到集合中
//LIN组合并且在循环接收数据中时才读取数据
@@ -1482,6 +1558,11 @@ namespace CapMachine.Wpf.Services
CanDriveService.UpdateSpeedCmdData(itemTag!.Value.EngSvValue);
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.CANFD:
//获取PLC的SV数据 更新SV的速度值到压缩机
CanFdDriveService.UpdateSpeedCmdData(itemTag!.Value.EngSvValue);
//itemTag.Value.EngPvValue = 0;
break;
case CanLinEnum.Lin:
//获取PLC的SV数据 更新SV的速度值到压缩机
LinDriveService.UpdateSpeedCmdData(itemTag!.Value.EngSvValue);
@@ -1552,6 +1633,10 @@ namespace CapMachine.Wpf.Services
//获取PLC的使能状态更新到CAN的使能状态
CanDriveService.UpdateCapEnableCmdData(OperateResultValue.Content[0] == 0 ? false : true);
break;
case CanLinEnum.CANFD:
//获取PLC的使能状态更新到CAN的使能状态
CanFdDriveService.UpdateCapEnableCmdData(OperateResultValue.Content[0] == 0 ? false : true);
break;
case CanLinEnum.Lin:
//获取PLC的使能状态更新到LIN的使能状态
LinDriveService.UpdateCapEnableCmdData(OperateResultValue.Content[0] == 0 ? false : true);
@@ -1583,6 +1668,10 @@ namespace CapMachine.Wpf.Services
//获取PLC的 PTC使能更新到CAN的 PTC使能
CanDriveService.UpdateCapPTCEnableCmdData(OperateResultValue.Content[20] == 0 ? false : true);
break;
case CanLinEnum.CANFD:
//获取PLC的 PTC使能更新到CAN的 PTC使能
CanFdDriveService.UpdateCapPTCEnableCmdData(OperateResultValue.Content[20] == 0 ? false : true);
break;
case CanLinEnum.Lin:
//获取PLC的 PTC使能更新到LIN的 PTC使能
LinDriveService.UpdateCapPTCEnableCmdData(OperateResultValue.Content[20] == 0 ? false : true);
@@ -1598,6 +1687,10 @@ namespace CapMachine.Wpf.Services
//获取PLC的 PTC功率更新到CAN的 PTC功率
CanDriveService.UpdateCapPTCPwCmdData(OperateResultValue.Content[22]);
break;
case CanLinEnum.CANFD:
//获取PLC的 PTC功率更新到CAN的 PTC功率
CanFdDriveService.UpdateCapPTCPwCmdData(OperateResultValue.Content[22]);
break;
case CanLinEnum.Lin:
//获取PLC的 PTC功率更新到LIN的 PTC功率
LinDriveService.UpdateCapPTCPwCmdData(OperateResultValue.Content[22]);
@@ -1613,6 +1706,10 @@ namespace CapMachine.Wpf.Services
//获取PLC的 PTC水流量信号更新到CAN的 PTC水流量信号
CanDriveService.UpdateCapPTCFlowCmdData(OperateResultValue.Content[24]);
break;
case CanLinEnum.CANFD:
//获取PLC的 PTC水流量信号更新到CAN的 PTC水流量信号
CanFdDriveService.UpdateCapPTCFlowCmdData(OperateResultValue.Content[24]);
break;
case CanLinEnum.Lin:
//获取PLC的 PTC水流量信号更新到LIN的 PTC水流量信号
LinDriveService.UpdateCapPTCFlowCmdData(OperateResultValue.Content[24]);
@@ -1628,6 +1725,10 @@ namespace CapMachine.Wpf.Services
//获取PLC的 PTC水温更新到CAN的 PTC水温
CanDriveService.UpdateCapPTCWaterTempCmdData(OperateResultValue.Content[26]);
break;
case CanLinEnum.CANFD:
//获取PLC的 PTC水温更新到CAN的 PTC水温
CanFdDriveService.UpdateCapPTCWaterTempCmdData(OperateResultValue.Content[26]);
break;
case CanLinEnum.Lin:
//获取PLC的 PTC水温更新到LIN的 PTC水温
LinDriveService.UpdateCapPTCWaterTempCmdData(OperateResultValue.Content[26]);